Figure 16: Filesystem Lock Jumper
2.6 Manual Override
The Manual Override is provided to allow the GLK12232-25 to be reset to some of its factory defaults.
This can be particularly helpful if the display module has been set to an unknown baud rate or I
2
C Slave
Address and you are no longer able to communicate with it. If you wish to return the module to its default
settings you must:
1. Power off the display module.
2. Place a Jumper on the Manual Override pins 1 and 2 as pictured below.
3. Power up the display module.
4. The display module is now set to its default values listed below in table 3.
5. Edit and save settings.
Matrix Orbital GLK12232-25 11